| Version # |
Date Released |
Changes from previous version |
| 6.00.0 |
July 22, 2008
|
|
| 5.02.0 |
June 30, 2008
|
- Powerful Unique Waveform Decode Functionality
- Including CAN, LIN, 8B10B, FlexRay, I2C, and SPI
- Eye Mask Multi-Margin
- FBDIMM Compliance Test
|
| 5.01.0 |
May 23, 2008
|
- Advanced Exploration Capabilities - Watch Video
- FlexRay and CAN Decode and Masks
- Improved Compliance Test Functionality within ScriptBuilder
- Deep Memory Support
|
| 5.00.0 |
February 6, 2008
|
- Hidden Anomaly Location
- ScopeView Animation
- DisplayPort Compliance Test
- DVI Compliance Test
- PCI-Express 2.0 Compliance Test
|
| 4.10.0 |
May 4, 2007
|
- Column vs. Column plotting
- Integrate M1 OT into your lab automation
- 8B/10B decode
- C# Support
|
| 4.09.0 |
March 21, 2007
|
- Scope View Animation
- I2C Triggering
- PLL Transfer Function
|
| 4.08.0 |
February 20, 2007
|
- Unattended Fault Detection
- I2C Compliance Test
- I2C Decode
- HDMI Compliance Test Capability
- Overshoot/Undershoot Area & Ringback
- Scope Animation
|
| 4.07.0 |
Dec 1, 2006
|
-
Extended Memory
-
MATLAB support
-
FFT of Voltage-vs-time
-
Plot column in Characterization Manager
-
Multiple-threshold-level RjDj Bathtub Curve
-
Limit-Relative measurements in Event Triggering/RunUntil
-
Looping and branching in TestScripts
|
| 4.06.1 |
Aug 29, 2006
|
-
M1 Virtual Deep Memory control
-
Modified scope information display on printouts/reports
-
Bathtub curve now displays properly in cases where the tails cross
-
Fixed an issue with item placement in ScriptBuilder
-
Repaired a small issue in Characterization Manager saving when the stat name has parentheses in it
-
Repaired the differential RT/FT when positive-rail High/Low TimeTags are not available
|
| 4.06 |
Aug 15, 2006
|
-
SuperMAQ – User-defined measurement statistics versus acquisition view
-
M1 Virtual Deep Memory™ introduced (MAQ, SuperMAQ, Record/Playback; Memory aggregation is coming soon)
-
- Reorganized the display for more vertical space in stacked mode – the legend moves to left side instead of below
- ScopeTrack width can now be changed directly
- Zoom To list with quick zoom choices
- Support for PgUp/PgDn/arrows on zoom/pan
- ScopeView Single Y-Axis mode - Turn individual channels on/off
- LogicView changes so it lines up with a single-axis ScopeView
- Markers will now cross over one another and the marker read out will track appropriate
- Ability
to control M1 Oscilloscope Tools™ externally from a user-created
program - New product option for enterprise customers only
- Undo in M1 ScriptBuilder™ (unlimited levels)
-
Flexible text output formatting - User can choose print-pretty or Excel-pretty for text saving
-
New Measurements (now M1 Oscilloscope Tools™ has over 250 measurements)
- Differential risetime/falltime for Negative rail or Both rails
- FFT x-axis Log scaling
-
Support for new oscilloscope families
- LeCroy SDA9000
- LeCroy 18000
- Yokogawa DL9040
- Tektronix DPO/DSA70000
-
Minor Bug Repairs
- Zoom to N Cycles is now working properly at the beginning/end of the acquisition
- MAQ Clear now allows recalculation of units with next acquisitions
- MAQ printing is working properly
|
| 4.05 |
Feb 6, 2006
|
-
Delay RjDj (i.e. RjDj relative to an explicit clock)
-
Ability to control M1™ on the scope from another M1™ on a remote machine
-
Ability to run an M1 TestScript™ from an external controller
-
Stepper Motor counting measurement for printer applications
-
Upsample is now controlled in the Channel Settings tab, on the same
dialog where thresholds are set. This Upsample value is now global - it
will affect every measurement where that signal is involved (e.g. a
Period measurement or a Delay RjDj measurement)
-
Delay to N is now available for any Delay measurement in which the clock signal is being Upsampled.
-
All four standard M1™ data file types (VvT, TvT, RAW, TTL) are now
associated with M1™. This means that you can double-click on e.g. a VvT
file, and M1™ will automatically start up and load that file.
-
Save user-defined eye mask -- user defined masks will pull up in the standard masks pull-down list menu
-
Show TestScript report starting with first acquisition, with live update on each acquisition
-
Mode to run exactly N acquisitions/time
-
Mode to put up a 'this computer busy' screen during sequence acquisitions
-
Basic report format is now implemented for Save Multiple feature; the
pre-defined results report template that has a header with info at the
top and then one section for each open View. An image of the View will
be included, along with the basic Stats.
-
Spread Spectrum Clocking (SSC) modulation and magnitude measurement view via external .dll
|
| 4.04.2 |
Oct 19, 2005
|
-
Upsample - for use when data and clocks are at different frequencies
-
Delay to N - For upsampled clocks. Enables users to select how many
clock edges to delay to for making jitter measurements.
-
RjDj Decomposition can now be done on Clock signals
-
"Rerun AutoMeasure" button in button drop-list above stats area
-
"Restore Factory Defaults" button in the "Preferences" menu tab
-
Hourglass cursor during potentially long operations
-
Improved upon a Windows-related issue where ToolTips were not always showing up.
-
If SEEj™ detects fewer than 3 complete repetitions of the pattern in a
single acquisition it will treat that measurement as it does "live
traffic" patterns.
-
Improvements to markers usability and readout
-
Eliminated a potential infinite loop in SEEj™
-
Repaired a number of TestScript and ScriptBuilder issues so that
developing and running TestScripts is reliable
-
Fixed a problem where the stats, but not the display, was accumulating for HistoView
-
Corrected a problem where LogicView information was not saving properly
-
Fixed a problem where Markers on a MultiAcqView column plot were not working properly
-
Fixed an issue where the y-axis units on an EyeView were showing as Seconds rather than Volts
|
| 4.04 |
Sept 2005
|
|
| 4.03 |
30 June 2005
|
-
Agilent MSO/DSO-6000 Support
-
LogicView™
-
Serial/Pattern triggering
-
The new family of M1™ Advanced Oscilloscope Tools™
-
Margin testing on eye diagrams
-
Calculate statistics between markers only
-
Software PLL (1st order)
-
USB TMB support
-
Actual measurement results are now printed on TestScript report
-
Multi-segment TestScript report summary
-
Various other improvements and small enhancements
|
| 4.02.1 |
19 April 2005
|
-
Modified VvT file format to support future functionality
-
Added Summary display for TestScripts with more than one segment
-
All TestScript™ results can now be either printed or saved to a text file
-
Modified some colors for better visibility
-
Fixed a problem where Rise/Falltime would not work correctly for a differential signal
-
Fixed some TestScript-related issues to improve performance and support the SATA II TestScript
-
Updated HP/AT54845/6 support (no more Query UNTERMINATED messages)
-
Fixed a problem where toggling Graphics On/Off in a MultiAcqView would cause a duplicate record
|
| 4.02.0 |
4 April 2005
|
-
User-developed Custom M1 Measurements: Users can now create their own,
unique, user-defined measurements in a DLL and call them from the front
panel of M1 or can call them in an M1 TestScript.
-
Improvements on the TestScript Pass/Fail screen. The report screen can
now be given a title by the user. The variable names for each
specification value can be specified
-
Two new delay parameters for situations where Clock & Data are
different frequencies, including: Upsample Clock by a factor of N and
Delay to Nth edge of data.
-
DDj versus Bit display (for Repetitive Data only)
-
When in Multi-Acquisition view, it is now possible to plot any column
of data versus acquisition number as either a TimeView or a HistoView.
-
Vpeak-peak, Vamplitude, and Vrms statistics added to ScopeView
|
| 4.01.0 |
24 Feb 2005
|
-
-
Save/Recall Views in a settings file now available... Press Save |
Multiple Items... | Views Note: Choosing Preferences | Save Settings
does not include Views, but Preferences | Load Settings will load any
Views that were saved with those settings.
-
Risetime/Falltime views now allow the selection of V/ns or ns/V units in addition to Time
-
HP 54720 oscilloscope support
-
A number of other smaller improvements
|
| 4.00.0 |
15 Feb 2005
|
-
Initial release of M1 v4
-
AutoMeasure™
-
M1 Reader™
-
M1 NewComer™
-
Record/Playback Console
-
MAQ Save Worst Case
-
Compliance Test Tools
-
Compliance Test Tool Builder
-
Logging
-